Product Datasheet

Commercial PCS (Built-in Transformer) 50K / 100K / 250K-TT

 

 

 

Product Features

Can be used in high-altitude, alpine areas

Power frequency topology, industrial design

AC and DC dual power backup, ensure the power supply of the control system

High power density, Max. efficiency up to 97.6%

High-performance DSP, optimized control circuit design, better performance

Wide DC input voltage range design, compatible with various batteries

Functions of grid connected charging & discharging and off-grid independent inverter

Reactive power and active power are adjustable

Support diesel generator access, seamless switching between on-grid and off-grid (optional)

Cold start with load, Three-phase 100% unbalanced load, strong load adaptability

Friendly grid adaptability, accept power grid dispatch

Intelligent management control strategy, multiple working modes, online or remote switching

 

 

Technical Specifications

 

 

 

 

Model

LEG-50K-TT

LEG-100K-TT

LEG-250K-TT

DC Input (PV)

 

 

 

Max. DC Voltage [V]

850

Operating Voltage range [V]

500 ~ 850

AC output (On Grid)

 

 

 

Rated Power [kW]

50

100

250

Max. AC Power [kVA]

55

110

275

Max. AC Current [A]

79

159

397

Rated Grid Voltage [V]

400

Rated Grid Frequency [Hz]

50/60

Rated Frequency Range [Hz]

45 ~ 55/55 ~ 65

Power Factor at Rated Power

>0.99

THDi

<3% (Rated power)

Power Factor

0.9 leading to 0.9 lagging

AC Output System

3W/N/PE

AC Output (Off Grid)

 

 

 

Rated Output Power [kW]

50

100

250

Max.Output Power [kVA]

55

110

275

Rated Output Voltage [V]

400

Rated Frequency [Hz]

50/60

THDi

<3% (Linear load)

Unbalanced Load Capacity

100%

Protection Function

 

 

 

DC Overvoltage Protection

Yes

DC Short Circuit Protection

Yes

AC Overvoltage Protection

Yes

Polarity Reverse Protection

Yes

Module Temperature Protection

Yes

Efficiency

 

 

 

Max. Efficiency

96.0%

97.0%

General Parameters

 

 

 

Dimensions (W*D*H)[mm]

1000*800*2015

1000*1050*2260

Net Weight [kg]

650

750

1600

Isolation Transformer

Yes

Operating Temperature Range [℃]

-30 ~ +55

Shutdown Self power Consumption [W]

<50

Cooling Mode

Forced air cooling

Installation Style

IP20

Relative Humidity

0 ~ 95%,non-condensing

Max. Altitude [m]

5000 (3000 Derating)

Display Mode

Touch screen

Dispatching Communication Mode

EthernetRS485

BMS Communication Mode

RS485CAN

Communication Protocol

ModbusIEC104

laisser un message